Selection Guide | |||||||
Certification |
Part No. | Input Voltage(VDC) | Output | Full Load Efficiency② (%)Min./Typ. | Capacitive Load (µF)Max. | ||
Nominal ( Range) | Max.① | Voltage(VDC) | Current(mA) Max./Min. | ||||
CFDM60-48S05 |
48 (18-75) |
80 | 5.0 | 12000/0 | 90/92.5 | 20000 | |
CFDM60-48S12 | 12 | 5000/0 | 91/93 | 5000 | |||
CFDM60-48S15 | 15 | 4000/0 | 91/93.3 | 3500 | |||
CFDM60-48S24 | 24 | 2500/0 | 91/93.8 | 2000 | |||
Notes : ①Exceeding the maximum input voltage may cause permanent damage; ②Efficiency is measured at nominal input voltage and rated output load. | |||||||